I tackle a mains PRV choking water pressure in Harrow, then head over to Romford to swap a seized Danfoss 3-port valve. I bunged the F&E tank in the loft to save a full drain-down, but testing the heating uncovered a whole new issue with the room stat wiring.
Watch the full diagnostic breakdown and drop your thoughts in the comments ππ½
You know that sinking feeling when you lift a floorboard for a "straightforward" radiator swap, and your moral compass immediately ruins your afternoon?
New video drops tonight at 6. Weβre digging into a hidden leak, dodgy auto-fill setups, and why quotes for radiators are never just about hanging metal on a wall ππ½
Most heating engineers refuse to touch bespoke curved bay radiators, and after taking this one on solo, I completely understand why! Zero margin for error, custom bracket alignments, and pipework that has to land bang on the money.
Plus, in this weekβs upload:
β’ Fitting a system bypass valve (press fit saves the day)
β’ Replacing a leaking unvented cylinder TPRV
β’ Hunting down an annoying boiler pressure drop
Tap the link to watch the full video and let me know in the comments, would you tackle one of these curved installs yourself, or leave well alone? ππ½
Delayed video today, it'll be up tonight. Been a busy week and ended with celebrating love with an old friend's wedding up in Yorkshire β₯οΈ hope you've all had a great weekend π
Never be too proud to leave your pride at the door and crack open the manufacturer's instructions. In todayβs upload, I get stuck into a floor-standing Glow-worm Ultrapower SXi that I havenβt done a full strip-down service on before, featuring a rigid gas line setup that definitely wasn't worth just "winging".
After that, I head over to a Viessmann Vitodens 100-W locking out on an F2 overheat fault on domestic hot water, where we pull the plate heat exchanger and clear out a solid blockage with spirits of salts.
Grab a brew and check it out! Let me know in the comments how you handle boilers you don't see every day ππ½
Ever turned up to what should be a routine valve swap, only to find the installer left you absolutely ZERO play in the pipework?
In this one, I run through a busy day on the tools, troubleshooting a seized zone valve, wiring up a Hive system to an Intergas boiler, and getting into a proper wrestling match with a Vaillant ecoTEC 837.
Recalls are easily the most frustrating part of the trade, but when a quick fix doesn't hold up and you have to go back to do it the "long way", how do you handle the pricing?
In tonight's video, Iβm back on a Worcester Bosch boiler sorting a stubborn plate heat exchanger that kept short cycling. After testing chemical siphoning first to save the client money, I had to drop the plate out properly from behind the manifold.
At the end of the video, I break down exactly what I invoiced them β but I want to know what you would do:
Eat the cost completely as a callback guarantee?
Charge full labor for both visits?
Just bill the difference between the jobs?
Check out the upload, see how the fix went down, and drop your take in the comments! ππ½
Battling 34Β°C heat on the last job before the holiday! I was running a new external 22mm gas line to a boiler, started off with a low route planned around the doors and fence, then scrapped it mid-job to take it up over the flat roof.
Doing that saved a mountain of elbow fittings, eliminated flow restriction, and kept the pipework clean with some proper bends.
Would you have stuck to the low route, or was going over the roof the right call?
Β£800+ for a new main heat exchanger... or Β£250 reconditioned? π§°
In tonight's video, we tackle a split heat exchanger on a Vaillant ecoTEC Plus 838 after customer service refused to even quote the repair without charging a call-out fee first.
Full teardown, flue turret tricks, and the complete rebuild drops tonight at 6!
Quick question for the installers:
What manufacturer has given you the biggest headache with tech support/customer service recently? ππ½
CP Utility Solutions
I tackle a mains PRV choking water pressure in Harrow, then head over to Romford to swap a seized Danfoss 3-port valve. I bunged the F&E tank in the loft to save a full drain-down, but testing the heating uncovered a whole new issue with the room stat wiring.
Watch the full diagnostic breakdown and drop your thoughts in the comments ππ½
https://youtu.be/EPaS0OqUzoQ
16 hours ago | [YT] | 8
View 0 replies
CP Utility Solutions
You know that sinking feeling when you lift a floorboard for a "straightforward" radiator swap, and your moral compass immediately ruins your afternoon?
New video drops tonight at 6. Weβre digging into a hidden leak, dodgy auto-fill setups, and why quotes for radiators are never just about hanging metal on a wall ππ½
4 days ago | [YT] | 15
View 0 replies
CP Utility Solutions
"The Hardest Radiator Install In The UK?"
Most heating engineers refuse to touch bespoke curved bay radiators, and after taking this one on solo, I completely understand why! Zero margin for error, custom bracket alignments, and pipework that has to land bang on the money.
Plus, in this weekβs upload:
β’ Fitting a system bypass valve (press fit saves the day)
β’ Replacing a leaking unvented cylinder TPRV
β’ Hunting down an annoying boiler pressure drop
Tap the link to watch the full video and let me know in the comments, would you tackle one of these curved installs yourself, or leave well alone? ππ½
https://youtu.be/mMpsa-ZY-ZA
1 week ago | [YT] | 17
View 7 replies
CP Utility Solutions
Quick question for the engineers and trades on here ππ½
You turn up to a boiler breakdown, pull off the casing, and realize the part ordered/brought is completely wrong. Whatβs your first move?
A) Hunt through the van racking praying for a spare π
B) Drop everything and race to the nearest merchant ππ½ββοΈ
C) Reschedule with the customer ποΈ
D) Find a clever workaround on site π§
New vlog drops tonight at 6 showing how a nightmare start to the morning turned into one of our smoothest installs yet! π¬
1 week ago | [YT] | 9
View 2 replies
CP Utility Solutions
Delayed video today, it'll be up tonight. Been a busy week and ended with celebrating love with an old friend's wedding up in Yorkshire β₯οΈ hope you've all had a great weekend π
#wedding #yorkshire #love #husbandandwife #newlyweds
2 weeks ago | [YT] | 98
View 17 replies
CP Utility Solutions
New vlog is live tonight at 6!
Never be too proud to leave your pride at the door and crack open the manufacturer's instructions. In todayβs upload, I get stuck into a floor-standing Glow-worm Ultrapower SXi that I havenβt done a full strip-down service on before, featuring a rigid gas line setup that definitely wasn't worth just "winging".
After that, I head over to a Viessmann Vitodens 100-W locking out on an F2 overheat fault on domestic hot water, where we pull the plate heat exchanger and clear out a solid blockage with spirits of salts.
Grab a brew and check it out! Let me know in the comments how you handle boilers you don't see every day ππ½
2 weeks ago | [YT] | 13
View 0 replies
CP Utility Solutions
New video is live! π₯
Ever turned up to what should be a routine valve swap, only to find the installer left you absolutely ZERO play in the pipework?
In this one, I run through a busy day on the tools, troubleshooting a seized zone valve, wiring up a Hive system to an Intergas boiler, and getting into a proper wrestling match with a Vaillant ecoTEC 837.
Check out the full upload here: https://youtu.be/l3JPu8F2fqs
Let me know what you think in the comments! ππ½
3 weeks ago | [YT] | 10
View 0 replies
CP Utility Solutions
Did I handle this customer bill fairly? π οΈ
Recalls are easily the most frustrating part of the trade, but when a quick fix doesn't hold up and you have to go back to do it the "long way", how do you handle the pricing?
In tonight's video, Iβm back on a Worcester Bosch boiler sorting a stubborn plate heat exchanger that kept short cycling. After testing chemical siphoning first to save the client money, I had to drop the plate out properly from behind the manifold.
At the end of the video, I break down exactly what I invoiced them β but I want to know what you would do:
Eat the cost completely as a callback guarantee?
Charge full labor for both visits?
Just bill the difference between the jobs?
Check out the upload, see how the fix went down, and drop your take in the comments! ππ½
π https://youtu.be/RH_b7DpHg24
3 weeks ago | [YT] | 12
View 0 replies
CP Utility Solutions
Battling 34Β°C heat on the last job before the holiday! I was running a new external 22mm gas line to a boiler, started off with a low route planned around the doors and fence, then scrapped it mid-job to take it up over the flat roof.
Doing that saved a mountain of elbow fittings, eliminated flow restriction, and kept the pipework clean with some proper bends.
Would you have stuck to the low route, or was going over the roof the right call?
Watch the full job & pipe bending walkthrough now!
https://youtu.be/SazE3PK7VnQ
Let me know your thoughts in the comments ππ½
4 weeks ago | [YT] | 10
View 0 replies
CP Utility Solutions
Β£800+ for a new main heat exchanger... or Β£250 reconditioned? π§°
In tonight's video, we tackle a split heat exchanger on a Vaillant ecoTEC Plus 838 after customer service refused to even quote the repair without charging a call-out fee first.
Full teardown, flue turret tricks, and the complete rebuild drops tonight at 6!
Quick question for the installers:
What manufacturer has given you the biggest headache with tech support/customer service recently? ππ½
Vaillant
Worcester Bosch
Ideal
Baxi / Potterton
1 month ago | [YT] | 26
View 1 reply